Whole-house air changes per hour for each wind direction (blue), the lower of simulation and textbook calculation. The dashed red ring is the target. Whole-house ACH = fresh air entering the house / total indoor volume.
| Room | N | E | S | W | Worst, dm³/s per m² | Result | Notes |
|---|---|---|---|---|---|---|---|
| R1 main room · 23.9 m² | 100.3 | 0.0 | 83.0 | 0.0 | 0.0 < 3 | Below target | |
| R2 room · 21.3 m² | 101.8 | 0.0 | 114.8 | 0.0 | 0.0 < 3 | Below target | |
| R3 hall / corridor · 7.1 m² | 292.4 | 0.0 | 328.1 | 0.0 | — | Not assessed | treated as hall / corridor (a guess from its size and shape); no window or door to the outside |
Green = at least the target plus that direction's uncertainty band; amber = within the band of the target; red = below. Values are the lower of simulation and textbook calculation, capped at the fresh air entering the house. Room volume = floor area × 2.50 m. dm³/s per m² = fresh air per m² of floor, shown against the Bbl purge-ventilation figures (3 for a verblijfsruimte, 6 for a verblijfsgebied) for orientation only; the formal check is NEN 1087.
| Wind from | Judged ACH | Simulated ACH | Fresh air in (L/s) | Air out (L/s) | In/out mismatch | Fluctuation | Note |
|---|---|---|---|---|---|---|---|
| N (0°) | 46.7 ±37% | 50.5 | 1835 | 1625 | 37% | 0% | in/out mismatch over 25% (steady): wider band |
| E (90°) | 0.0 ±50% | 0.0 | 0 | 847 | 100% | 0% | All open windows/doors face the same wind pressure, so wind alone drives no cross-flow (single-sided ventilation needs turbulence / temperature effects, not modelled). Change the wind direction or set roles by hand.; in/out mismatch over 25% (steady): wider band |
| S (180°) | 46.7 ±31% | 54.8 | 1990 | 1097 | 31% | 2% | in/out mismatch over 25% (steady): wider band |
| W (270°) | 0.0 ±50% | 0.0 | 0 | 783 | 100% | 0% | All open windows/doors face the same wind pressure, so wind alone drives no cross-flow (single-sided ventilation needs turbulence / temperature effects, not modelled). Change the wind direction or set roles by hand.; in/out mismatch over 25% (steady): wider band |
Each direction recalculated with hand-calculation methods that do not use the simulation, with the same opening sizes and facade pressures. Orifice network: every room is a zone at its own pressure and every open window and door (interior doors included) is an orifice, Q = Cd·A·√(2Δp/ρ); the room pressures are solved so each room's flows balance (the multizone method of CIBSE AM10 and CONTAM). Single zone: BS 5925 cross-ventilation, inlets and outlets in series and interior walls ignored. Discharge coefficient Cd = 0.6; the range in brackets is Cd 0.5–0.7.
| Wind from | Simulated fresh air (L/s) | Orifice network (L/s) | Single zone (L/s) | Simulated / network | Result | Note |
|---|---|---|---|---|---|---|
| N | 1835 | 1697 (1414–1980) | 4333 | 1.08 (0.53–1.59) | Agrees | |
| E | 0 | 0 (0–0) | 0 | — (0.42–1.75) | No flow (both) | |
| S | 1990 | 1697 (1414–1980) | 4333 | 1.17 (0.58–1.53) | Agrees | |
| W | 0 | 0 (0–0) | 0 | — (0.42–1.75) | No flow (both) |
Agreement range: Cd 0.5–0.7, widened by that direction's uncertainty band.
| Room ACH: simulated / network | N | E | S | W |
|---|---|---|---|---|
| R1 | 100.3 / 102.3 | 0.0 / 0.0 | 83.0 / 102.3 | 0.0 / 0.0 |
| R2 | 101.8 / 114.8 | 0.0 / 0.0 | 120.5 / 114.8 | 0.0 / 0.0 |
| R3 | 292.4 / 344.5 | 0.0 / 0.0 | 328.1 / 344.5 | 0.0 / 0.0 |
| Id | Type | Position | Setting | N | E | S | W |
|---|---|---|---|---|---|---|---|
| D1 | door 0.90 m | interior | Open | 1386 | 34 | 1766 | 140 |
| D2 | door 0.90 m | interior | Open | 1495 | 131 | 1466 | 18 |
| W1 | window 2.40 m | S facade | Auto | 47 out | 171 out | 1053 in | 255 out |
| D3 | door 0.90 m | S facade | Auto | 1578 out | 214 out | 744 in | 170 out |
| W2 | window 1.90 m | N facade | Auto | 1050 in | 245 out | 1097 out | 259 out |
| D4 | door 0.90 m | N facade | Auto | 785 in | 217 out | 192 in | 98 out |
Settings "Auto" become an inlet or an outlet depending on the wind (green = air in, blue = air out). Interior doors show the air passing through them.
Colour = air speed (blue slow, red fast); white streaks follow the air. Snapshots taken at the end of each case.
For each wind direction the plan was simulated as a 2D incompressible flow (grid 320 × 184 cells, 13.7 cells per metre, LES turbulence model). Each window and door to the outside was held at the wind pressure of its facade, 0.5·ρ·U²·Cp. The flow was allowed to settle for two flow-through times (Study Length "Standard") and then sampled 8 times. The flow through each opening was integrated on the faces between the indoor air and the opening.
Generated by OTOM CFD (WebGPU), House Ventilation tab. Every number in this report comes from the simulation or the textbook calculation; the recommendation wording follows fixed rules.