Whole-house air changes per hour for each wind direction (blue), the lower of simulation and textbook calculation. The dashed red ring is the target. Whole-house ACH = fresh air entering the house / total indoor volume.
| Room | N | NE | E | SE | S | SW | W | NW | Worst, dm³/s per m² | Result | Notes |
|---|---|---|---|---|---|---|---|---|---|---|---|
| R1 main room · 51.9 m² | 75.7 | 10.5 | 20.4 | 115.5 | 151.4 | 25.4 | 153.6 | 115.5 | 7.7 ≥ 6 | Pass | |
| R2 room · 22.5 m² | 87.2 | 135.6 | 180.3 | 68.9 | 174.3 | 135.6 | 91.7 | 68.9 | 50.8 ≥ 6 | Pass | |
| R3 room · 12.6 m² | 154.8 | 242.5 | 322.4 | 39.6 | 309.6 | 242.5 | 54.3 | 40.8 | 29.2 ≥ 6 | Pass |
Green = at least the target plus that direction's uncertainty band; amber = within the band of the target; red = below. Values are the lower of simulation and textbook calculation, capped at the fresh air entering the house. Room volume = floor area × 2.65 m. dm³/s per m² = fresh air per m² of floor, shown against the Bbl purge-ventilation figures (3 for a verblijfsruimte, 6 for a verblijfsgebied) for orientation only; the formal check is NEN 1087.
| Wind from | Judged ACH | Simulated ACH | Fresh air in (L/s) | Air out (L/s) | In/out mismatch | Fluctuation | Note |
|---|---|---|---|---|---|---|---|
| N (0°) | 67.6 ±12% | 74.0 | 4738 | 5388 | 12% | 0% | |
| NE (45°) | 35.0 ±26% | 35.8 | 2293 | 3092 | 26% | 1% | in/out mismatch over 25% (steady): wider band |
| E (90°) | 46.6 ±36% | 48.2 | 3087 | 4808 | 36% | 1% | in/out mismatch over 25% (steady): wider band |
| SE (135°) | 69.0 ±24% | 110.6 | 7082 | 5411 | 24% | 0% | |
| S (180°) | 135.1 ±18% | 197.7 | 12662 | 10367 | 18% | 0% | |
| SW (225°) | 35.0 ±39% | 52.2 | 3342 | 2049 | 39% | 0% | in/out mismatch over 25% (steady): wider band |
| W (270°) | 91.7 ±10% | 121.3 | 7766 | 8616 | 10% | 0% | |
| NW (315°) | 69.0 ±10% | 92.5 | 5922 | 6375 | 7% | 0% |
Each direction recalculated with hand-calculation methods that do not use the simulation, with the same opening sizes and facade pressures. Orifice network: every room is a zone at its own pressure and every open window and door (interior doors included) is an orifice, Q = Cd·A·√(2Δp/ρ); the room pressures are solved so each room's flows balance (the multizone method of CIBSE AM10 and CONTAM). Single zone: BS 5925 cross-ventilation, inlets and outlets in series and interior walls ignored. Discharge coefficient Cd = 0.6; the range in brackets is Cd 0.5–0.7.
| Wind from | Simulated fresh air (L/s) | Orifice network (L/s) | Single zone (L/s) | Simulated / network | Result | Note |
|---|---|---|---|---|---|---|
| N | 4738 | 4327 (3606–5048) | 4783 | 1.09 (0.73–1.31) | Agrees | |
| NE | 2293 | 2244 (1870–2618) | 3248 | 1.02 (0.62–1.47) | Agrees | |
| E | 3087 | 2984 (2487–3481) | 4318 | 1.03 (0.54–1.58) | Agrees | |
| SE | 7082 | 4416 (3680–5152) | 4547 | 1.60 (0.64–1.44) | Simulation higher | |
| S | 12662 | 8654 (7211–10096) | 9566 | 1.46 (0.68–1.38) | Simulation higher | |
| SW | 3342 | 2244 (1870–2618) | 3248 | 1.49 (0.51–1.62) | Agrees | |
| W | 7766 | 5871 (4893–6850) | 6045 | 1.32 (0.75–1.28) | Simulation higher | |
| NW | 5922 | 4416 (3680–5152) | 4547 | 1.34 (0.75–1.28) | Simulation higher |
Agreement range: Cd 0.5–0.7, widened by that direction's uncertainty band.
| Room ACH: simulated / network | N | NE | E | SE | S | SW | W | NW |
|---|---|---|---|---|---|---|---|---|
| R1 | 97.9 / 75.7 | 10.5 / 25.4 | 20.4 / 33.7 | 163.4 / 115.5 | 220.7 / 151.4 | 34.4 / 25.4 | 203.1 / 153.6 | 154.9 / 115.5 |
| R2 | 118.8 / 87.2 | 138.5 / 135.6 | 186.6 / 180.3 | 85.8 / 68.9 | 273.8 / 174.3 | 190.8 / 135.6 | 155.1 / 91.7 | 111.9 / 68.9 |
| R3 | 210.7 / 154.8 | 247.7 / 242.5 | 333.5 / 322.4 | 39.6 / 40.8 | 417.6 / 309.6 | 301.1 / 242.5 | 130.9 / 54.3 | 89.0 / 40.8 |
| Id | Type | Position | Setting | N | NE | E | SE | S | SW | W | NW |
|---|---|---|---|---|---|---|---|---|---|---|---|
| W1 | window 2.00 m | S facade | Auto | 1874 in | 165 out | 439 out | 3210 in | 4833 in | 491 in | 336 out | 324 out |
| W2 | window 2.00 m | S facade | Auto | 1528 in | 171 out | 454 out | 2391 in | 4088 in | 705 in | 6092 out | 4471 out |
| W3 | window 2.00 m | S facade | Auto | 1335 in | 2483 out | 3458 out | 1052 in | 3741 in | 1752 in | 1134 out | 885 out |
| W4 | window 2.00 m | W facade | Auto | 3778 out | 274 out | 457 out | 5411 out | 7541 out | 394 in | 7766 in | 5922 in |
| W5 | window 1.40 m | E facade | Auto | 1609 out | 2293 in | 3087 in | 429 in | 2826 out | 2049 out | 1053 out | 694 out |
| D1 | door 0.90 m | interior | Open | 303 | 192 | 209 | 1483 | 416 | 1039 | 2630 | 1865 |
| D2 | door 0.80 m | interior | Open | 2292 | 3175 | 4220 | 304 | 4905 | 3525 | 1370 | 954 |
Settings "Auto" become an inlet or an outlet depending on the wind (green = air in, blue = air out). Interior doors show the air passing through them.
Colour = air speed (blue slow, red fast); white streaks follow the air. Snapshots taken at the end of each case.
For each wind direction the plan was simulated as a 2D incompressible flow (grid 320 × 184 cells, 17.8 cells per metre, LES turbulence model). Each window and door to the outside was held at the wind pressure of its facade, 0.5·ρ·U²·Cp. The flow was allowed to settle for three flow-through times (Study Length "Long") and then sampled 8 times. The flow through each opening was integrated on the faces between the indoor air and the opening.
Generated by OTOM CFD (WebGPU), House Ventilation tab. Every number in this report comes from the simulation or the textbook calculation; the recommendation wording follows fixed rules.